Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
1.
Biosensors (Basel) ; 13(4)2023 Apr 03.
Article in English | MEDLINE | ID: covidwho-2326319

ABSTRACT

Electrochemical sensors consisting of screen-printed electrodes (SPEs) are recurrent devices in the recent literature for applications in different fields of interest and contribute to the expanding electroanalytical chemistry field. This is due to inherent characteristics that can be better (or only) achieved with the use of SPEs, including miniaturization, cost reduction, lower sample consumption, compatibility with portable equipment, and disposability. SPEs are also quite versatile; they can be manufactured using different formulations of conductive inks and substrates, and are of varied designs. Naturally, the analytical performance of SPEs is directly affected by the quality of the material used for printing and modifying the electrodes. In this sense, the most varied carbon nanomaterials have been explored for the preparation and modification of SPEs, providing devices with an enhanced electrochemical response and greater sensitivity, in addition to functionalized surfaces that can immobilize biological agents for the manufacture of biosensors. Considering the relevance and timeliness of the topic, this review aimed to provide an overview of the current scenario of the use of carbonaceous nanomaterials in the context of making electrochemical SPE sensors, from which different approaches will be presented, exploring materials traditionally investigated in electrochemistry, such as graphene, carbon nanotubes, carbon black, and those more recently investigated for this (carbon quantum dots, graphitic carbon nitride, and biochar). Perspectives on the use and expansion of these devices are also considered.


Subject(s)
Biosensing Techniques , Nanotubes, Carbon , Electrodes , Electrochemistry , Electrochemical Techniques
2.
Biosensors (Basel) ; 13(4)2023 Mar 23.
Article in English | MEDLINE | ID: covidwho-2315555

ABSTRACT

Biosensors are analytical tools that can be used as simple, real-time, and effective devices in clinical diagnosis, food analysis, and environmental monitoring. Nanoscale functional materials possess unique properties such as a large surface-to-volume ratio, making them useful for biomedical diagnostic purposes. Nanoengineering has resulted in the increased use of nanoscale functional materials in biosensors. Various types of nanostructures i.e., 0D, 1D, 2D, and 3D, have been intensively employed to enhance biosensor selectivity, limit of detection, sensitivity, and speed of response time to display results. In particular, carbon nanotubes and nanofibers have been extensively employed in electrochemical biosensors, which have become an interdisciplinary frontier between material science and viral disease detection. This review provides an overview of the current research activities in nanofiber-based electrochemical biosensors for diagnostic purposes. The clinical applications of these nanobiosensors are also highlighted, along with a discussion of the future directions for these materials in diagnostics. The aim of this review is to stimulate a broader interest in developing nanofiber-based electrochemical biosensors and improving their applications in disease diagnosis. In this review, we summarize some of the most recent advances achieved in point of care (PoC) electrochemical biosensor applications, focusing on new materials and modifiers enabling biorecognition that have led to improved sensitivity, specificity, stability, and response time.


Subject(s)
Biosensing Techniques , Nanofibers , Nanostructures , Nanotubes, Carbon , Electrochemical Techniques/methods , Nanostructures/chemistry , Biosensing Techniques/methods
3.
Biosensors (Basel) ; 13(4)2023 Apr 18.
Article in English | MEDLINE | ID: covidwho-2295971

ABSTRACT

Herein, we report results of the studies relating to the development of an impedimetric, magnetic bead-assisted supersandwich DNA hybridization assay for ultrasensitive detection of Neisseria gonorrhoeae, the causative agent of a sexually transmitted infection (STI), gonorrhea. First, a conductive ink was formulated by homogenously dispersing carboxylated multiwalled carbon nanotubes (cMWCNTs) in a stable emulsion of terpineol and an aqueous suspension of carboxymethyl cellulose (CMC). The ink, labeled C5, was coated onto paper substrates to fabricate C5@paper conductive electrodes. Thereafter, a magnetic bead (MB)-assisted supersandwich DNA hybridization assay was optimized against the porA pseudogene of N. gonorrhoeae. For this purpose, a pair of specific 5' aminated capture probes (SCP) and supersandwich detector probes (SDP) was designed, which allowed the enrichment of target gonorrheal DNA sequence from a milieu of substances. The SD probe was designed such that instead of 1:1 binding, it allowed the binding of more than one T strand, leading to a 'ladder-like' DNA supersandwich structure. The MB-assisted supersandwich assay was integrated into the C5@paper electrodes for electrochemical analysis. The C5@paper electrodes were found to be highly conductive by a four-probe conductivity method (maximum conductivity of 10.1 S·cm-1). Further, the biosensing assay displayed a wide linear range of 100 aM-100 nM (109 orders of magnitude) with an excellent sensitivity of 22.6 kΩ·(log[concentration])-1. The clinical applicability of the biosensing assay was assessed by detecting genomic DNA extracted from N. gonorrhoeae in the presence of DNA from different non-gonorrheal bacterial species. In conclusion, this study demonstrates a highly sensitive, cost-effective, and label-free paper-based device for STI diagnostics. The ink formulation prepared for the study was found to be highly thixotropic, which indicates that the paper electrodes can be screen-printed in a reproducible and scalable manner.


Subject(s)
Biosensing Techniques , Gonorrhea , Nanotubes, Carbon , Humans , Neisseria gonorrhoeae/genetics , Nanotubes, Carbon/chemistry , Ink , DNA/analysis , Gonorrhea/diagnosis , Biosensing Techniques/methods , Electrochemical Techniques/methods , Electrodes
4.
J Nanobiotechnology ; 21(1): 69, 2023 Feb 28.
Article in English | MEDLINE | ID: covidwho-2288660

ABSTRACT

BACKGROUND: The rapid increase in production and application of carbon nanotubes (CNTs) has led to wide public concerns in their potential risks to human health. Single-walled CNTs (SWCNTs), as an extensively applied type of CNTs, have shown strong capacity to induce pulmonary fibrosis in animal models, however, the intrinsic mechanisms remain uncertain. RESULTS: In vivo experiments, we showed that accelerated senescence of alveolar type II epithelial cells (AECIIs) was associated with pulmonary fibrosis in SWCNTs-exposed mice, as well as SWCNTs-induced fibrotic lungs exhibited impaired autophagic flux in AECIIs in a time dependent manner. In vitro, SWCNTs exposure resulted in profound dysfunctions of MLE-12 cells, characterized by impaired autophagic flux and accelerated cellular senescence. Furthermore, the conditioned medium from SWCNTs-exposed MLE-12 cells promoted fibroblast-myofibroblast transdifferentiation (FMT). Additionally, restoration of autophagy flux with rapamycin significantly alleviated SWCNTs-triggered senescence and subsequent FMT whereas inhibiting autophagy using 3-MA aggravated SWCNTs-triggered senescence in MLE-12 cells and FMT. CONCLUSION: SWCNTs trigger senescence of AECIIs by impairing autophagic flux mediated pulmonary fibrosis. The findings raise the possibility of senescence-related cytokines as potential biomarkers for the hazard of CNTs exposure and regulating autophagy as an appealing target to halt CNTs-induced development of pulmonary fibrosis.


Subject(s)
Nanotubes, Carbon , Pulmonary Fibrosis , Humans , Animals , Mice , Nanotubes, Carbon/toxicity , Pulmonary Fibrosis/chemically induced , Alveolar Epithelial Cells , Autophagy , Fibroblasts
5.
Chembiochem ; 24(9): e202300030, 2023 05 02.
Article in English | MEDLINE | ID: covidwho-2276697

ABSTRACT

One of the main problems in developing immunosensors featuring carbon nanotubes (CNTs) is immobilizing antibodies (Abs) onto the CNT surface to afford selective binding to target antigens (Ags). In this work, we developed a practical supramolecular Ab conjugation strategy based on resorc[4]arene modifiers. To improve the Ab orientation on the CNTs surface and optimizing the Ab/Ag interaction, we exploited the host-guest approach by synthesizing two newly resorc[4]arene linkers R1 and R2 via well-established procedures. The upper rim was decorated with eight methoxyl groups to promote selective recognition of the fragment crystallizable (Fc ) region of the Ab. Moreover, the lower rim was functionalized with 3-bromopropyloxy or 3-azidopropiloxy substituents to bind the macrocycles on the multi-walled carbon nanotubes (MWCNTs) surface. Accordingly, several chemical modifications of MWCNTs were evaluated. After the morphological and electrochemical characterization of nanomaterials, the resorc[4]arene-modified MWCNTs were deposited onto a glassy carbon electrode surface to evaluate their potential applicability for label-free immunosensor development. The most promising system showed an improved electrode active area (AEL ) of almost 20 % and a site-oriented immobilization of the SARS-CoV-2 spike protein S1 antibody (Ab-SPS1). The developed immunosensor revealed a good sensitivity (23.64 µA mL ng-1 cm-2 ) towards the SPS1 antigen and a limit of detection (LOD) of 1.01 ng mL-1 .


Subject(s)
Biosensing Techniques , COVID-19 , Nanotubes, Carbon , Humans , Biosensing Techniques/methods , Nanotubes, Carbon/chemistry , Immunoassay , SARS-CoV-2 , Antibodies/chemistry , Antigens , Limit of Detection , Electrochemical Techniques/methods , Gold/chemistry
6.
Sci Rep ; 13(1): 3118, 2023 02 22.
Article in English | MEDLINE | ID: covidwho-2272680

ABSTRACT

We investigate the electronic response of single-walled carbon nanotubes (SWCNTs) and a carbon nanobelt (CNB) to N-linked and O-linked SARS-CoV-2 spike glycoproteins, using ab initio quantum mechanical approach. The CNTs are selected from three zigzag, armchair, and chiral groups. We examine the effect of carbon nanotube (CNT) chirality on the interaction between CNTs and glycoproteins. Results indicate that the chiral semiconductor CNTs clearly response to the presence of the glycoproteins by changing the electronic band gaps and electron density of states (DOS). Since the changes in the CNTs band gaps in the presence of N-linked are about two times larger than the changes in the presence of the O-linked glycoprotein, chiral CNT may distinguish different types of the glycoproteins. The same results are obtained from CNBs. Thereby, we predict CNBs and chiral CNTs have suitable potential in sequential analysis of N- and O-linked glycosylation of the spike protein.


Subject(s)
Biosensing Techniques , COVID-19 , Nanotubes, Carbon , Humans , SARS-CoV-2 , Semiconductors
7.
Biosensors (Basel) ; 13(1)2022 Dec 27.
Article in English | MEDLINE | ID: covidwho-2244478

ABSTRACT

Biosensors are modern engineering tools that can be widely used for various technological applications. In the recent past, biosensors have been widely used in a broad application spectrum including industrial process control, the military, environmental monitoring, health care, microbiology, and food quality control. Biosensors are also used specifically for monitoring environmental pollution, detecting toxic elements' presence, the presence of bio-hazardous viruses or bacteria in organic matter, and biomolecule detection in clinical diagnostics. Moreover, deep medical applications such as well-being monitoring, chronic disease treatment, and in vitro medical examination studies such as the screening of infectious diseases for early detection. The scope for expanding the use of biosensors is very high owing to their inherent advantages such as ease of use, scalability, and simple manufacturing process. Biosensor technology is more prevalent as a large-scale, low cost, and enhanced technology in the modern medical field. Integration of nanotechnology with biosensors has shown the development path for the novel sensing mechanisms and biosensors as they enhance the performance and sensing ability of the currently used biosensors. Nanoscale dimensional integration promotes the formulation of biosensors with simple and rapid detection of molecules along with the detection of single biomolecules where they can also be evaluated and analyzed critically. Nanomaterials are used for the manufacturing of nano-biosensors and the nanomaterials commonly used include nanoparticles, nanowires, carbon nanotubes (CNTs), nanorods, and quantum dots (QDs). Nanomaterials possess various advantages such as color tunability, high detection sensitivity, a large surface area, high carrier capacity, high stability, and high thermal and electrical conductivity. The current review focuses on nanotechnology-enabled biosensors, their fundamentals, and architectural design. The review also expands the view on the materials used for fabricating biosensors and the probable applications of nanotechnology-enabled biosensors.


Subject(s)
Biosensing Techniques , Nanoparticles , Nanostructures , Nanotubes, Carbon , Nanowires , Nanotechnology/methods , Biosensing Techniques/methods
8.
Sensors (Basel) ; 23(1)2022 Dec 30.
Article in English | MEDLINE | ID: covidwho-2240623

ABSTRACT

The coronavirus disease 2019 (COVID-19) pandemic has created an urgent need for accurate early diagnosis and monitoring. A label-free rapid electrochemical point-of-care (POC) biosensor for SARS-CoV-2 detection in human saliva is reported here to help address the shortcomings of traditional nucleic acid amplification methods and give a quantitative assessment of the viral load to track infection status anywhere, using disposable electrochemical sensor chips. A new chemical construct of gold nanoparticles (GNp) and thionine (Th) are immobilized on carboxylic acid functionalized carbon nanotubes (SWCNT-COOH) for high-performance biosensing. The sensor uses saliva with a one-step pretreatment and simple testing procedure as an analytical medium due to the user-friendly and non-invasive nature of its procurement from patients. The sensor has a response time of 5 min with a limit of detection (LOD) reaching 200 and 500 pM for the freely suspended spike (S) protein in phosphate buffer saline (PBS) and human saliva, respectively. The sensor's performance was also proven for detecting a COVID-19 pseudovirus in an electrolyte solution with a LOD of 106 copies/mL. The results demonstrate that the optimized POC sensor developed in this work is a promising device for the label-free electrochemical biosensing detection of SARS-CoV-2 and different species of viruses.


Subject(s)
Biosensing Techniques , COVID-19 , Metal Nanoparticles , Nanotubes, Carbon , Humans , SARS-CoV-2 , COVID-19/diagnosis , Gold , Point-of-Care Systems
9.
Biosensors (Basel) ; 13(1)2022 Dec 28.
Article in English | MEDLINE | ID: covidwho-2236357

ABSTRACT

In this work, we report on the development of a simple electrochemical immunosensor for the detection of D-dimer protein in human plasma samples. The immunosensor is built by a simple drop-casting procedure of chitosan nanoparticles (CSNPs) as biocompatible support, Protein A (PrA), to facilitate the proper orientation of the antibody sites to epitopes as a capture biomolecule, and the D-dimer antibody onto a carboxyl functionalized multi-walled carbon nanotubes screen printed electrode (MWCNTs-SPE). The CSNPs have been morphologically characterized by Scanning Electron Microscopy (SEM) and Dynamic Light Scattering (DLS) techniques. Successively, the electrochemical properties of the screen-printed working electrode after each modification step have been characterized by differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The resulting MWCNTs-CSNPs-PrA-D-dimer Ab immunosensor displays an optimal and promising platform for antibody immobilization and specific D-dimer detection. DPV has been used to investigate the antigen/antibody interaction at different D-dimer concentrations. The proposed voltammetric immunosensor allowed a linear range from 2 to 500 µg L-1 with a LOD of 0.6 µg L-1 and a sensitivity of 1.3 µA L µg-1 cm-2. Good stability and a fast response time (5 s) have been reported. Lastly, the performance of the voltammetric immunosensor has been tested in human plasma samples, showing satisfactory results, thus attesting to the promising feasibility of the proposed platform for detecting D-dimer in physiological samples.


Subject(s)
Biosensing Techniques , COVID-19 , Chitosan , Metal Nanoparticles , Nanotubes, Carbon , Humans , Biosensing Techniques/methods , Nanotubes, Carbon/chemistry , Immunoassay , COVID-19/diagnosis , Biomarkers , Prognosis , Antibodies , Metal Nanoparticles/chemistry , Electrodes , Chitosan/chemistry , Electrochemical Techniques , Limit of Detection , Gold/chemistry
10.
Anal Chim Acta ; 1238: 340639, 2023 Jan 15.
Article in English | MEDLINE | ID: covidwho-2120191

ABSTRACT

The false-negative result of nucleic acid testing is an important cause of continued spread of COVID-19, while SARS-CoV-2 RNA degradation during transportation and nucleic acid extraction can lead to false-negative results. Here, we investigated that single-walled carbon nanotubes (SCNTs) could protect RNA from degradation for at least 4 days at room temperature. By constructing magnetism-functionalized SCNTs (MSCNTs), we developed a method that enabled protection and simple extraction of SARS-CoV-2 RNA, and the RNA-bound MSCNTs can be directly used for reverse transcription polymerase chain reaction (RT-qPCR) detection. The experimental results showed that 1 µg of MSCNTs adsorbed up to 24 ng of RNA. Notably, the MSCNTs-based method for extracting SARS-CoV-2 RNA from simulated nasopharyngeal swabs and saliva samples with mean recovery rates of 103% and 106% improved the sensitivity of RT-qPCR detection by 8-32 fold in comparison to current common methods. This improvement was largely attributable to the protection of RNA, enabling increased RNA load for downstream assays.


Subject(s)
COVID-19 , Nanotubes, Carbon , Nucleic Acids , Humans , SARS-CoV-2/genetics , RNA, Viral/genetics , COVID-19/diagnosis
11.
Biosensors (Basel) ; 12(11)2022 Nov 08.
Article in English | MEDLINE | ID: covidwho-2109936

ABSTRACT

Quick label-free virus screening and highly sensitive analytical tools/techniques are becoming extremely important in a pandemic. In this study, we developed a biosensing device based on the silicon nanoribbon multichannel and dielectrophoretic controlled sensors functionalized with SARS-CoV-2 spike antibodies for the use as a platform for the detection and studding of properties of viruses and their protein components. Replicatively defective viral particles based on vesicular stomatitis viruses and HIV-1 were used as carrier molecules to deliver the target SARS-CoV-2 spike S-proteins to sensory elements. It was shown that fully CMOS-compatible nanoribbon sensors have the subattomolar sensitivity and dynamic range of 4 orders. Specific interaction between S-proteins and antibodies leads to the accumulation of the negative charge on the sensor surface. Nonspecific interactions of the viral particles lead to the positive charge accumulation. It was shown that dielectrophoretic controlled sensors allow to estimate the effective charge of the single virus at the sensor surface and separate it from the charge associated with the binding of target proteins with the sensor surface.


Subject(s)
Biosensing Techniques , COVID-19 , Nanotubes, Carbon , Humans , SARS-CoV-2 , Biosensing Techniques/methods , Pandemics , Antibodies, Viral
12.
Biosensors (Basel) ; 12(9)2022 Sep 06.
Article in English | MEDLINE | ID: covidwho-2009950

ABSTRACT

After the COVID-19 pandemic, the development of an accurate diagnosis and monitoring of diseases became a more important issue. In order to fabricate high-performance and sensitive biosensors, many researchers and scientists have used many kinds of nanomaterials such as metal nanoparticles (NPs), metal oxide NPs, quantum dots (QDs), and carbon nanomaterials including graphene and carbon nanotubes (CNTs). Among them, CNTs have been considered important biosensing channel candidates due to their excellent physical properties such as high electrical conductivity, strong mechanical properties, plasmonic properties, and so on. Thus, in this review, CNT-based biosensing systems are introduced and various sensing approaches such as electrochemical, optical, and electrical methods are reported. Moreover, such biosensing platforms showed excellent sensitivity and high selectivity against not only viruses but also virus DNA structures. So, based on the amazing potential of CNTs-based biosensing systems, healthcare and public health can be significantly improved.


Subject(s)
Biosensing Techniques , COVID-19 , Graphite , Nanostructures , Nanotubes, Carbon , Biosensing Techniques/methods , COVID-19/diagnosis , DNA, Viral , Humans , Nanostructures/chemistry , Nanotubes, Carbon/chemistry , Oxides , Pandemics
13.
Adv Colloid Interface Sci ; 303: 102653, 2022 May.
Article in English | MEDLINE | ID: covidwho-1838648

ABSTRACT

COVID-19 is caused via the SARS-CoV-2 virus, a lipid-based enveloped virus with spike-like projections. At present, the global epidemic of COVID-19 continues and waves of SARS-CoV-2, the mutant Delta and Omicron variant which are associated with enhanced transmissibility and evasion to vaccine-induced immunity have increased hospitalization and mortality, the biggest challenge we face is whether we will be able to overcome this virus? On the other side, warm seasons and heat have increased the need for proper ventilation systems to trap contaminants containing the virus. Besides, heat and sweating accelerate the growth of microorganisms. For example, medical staff that is in the front line use masks for a long time, and their facial sweat causes microbes to grow on the mask. Nowadays, efficient air filters with anti-viral and antimicrobial properties have received a lot of attention, and are used to make ventilation systems or medical masks. A wide range of materials plays an important role in the production of efficient air filters. For example, metals, metal oxides, or antimicrobial metal species that have anti-viral and antimicrobial properties, including Ag, ZnO, TiO2, CuO, and Cu played a role in this regard. Carbon nanomaterials such as carbon nanotubes, graphene, or derivatives have also shown their role well. In addition, natural materials such as biopolymers such as alginate, and herbal extracts are employed to prepare effective air filters. In this review, we summarized the utilization of diverse materials in the preparation of efficient air filters to apply in the preparation of medical masks and ventilation systems. In the first part, the employing metal and metal oxides is examined, and the second part summarizes the application of carbon materials for the fabrication of air filters. After examination of the performance of natural materials, challenges and progress visions are discussed.


Subject(s)
Air Filters , Anti-Infective Agents , COVID-19 , Nanotubes, Carbon , Aerosols , COVID-19/prevention & control , Humans , Masks , Oxides , SARS-CoV-2
14.
Chemosphere ; 302: 134775, 2022 Sep.
Article in English | MEDLINE | ID: covidwho-1821179

ABSTRACT

Various emerging organic micropollutants, such as pharmaceuticals, have attracted the interest of the water industry during the last two decades due to their insufficient removal during conventional water and wastewater treatment methods and increasing demand for pharmaceuticals projected to climate change-related impacts and COVID-19, nanosorbents such as carbon nanotubes (CNTs), graphene oxides (GOs), and metallic organic frameworks (MOFs) have recently been extensively explored regarding their potential environmental applications. Due to their unique physicochemical features, the use of these nanoadsorbents for organic micropollutans in water and wastewater treatment processes has been a rapidly growing topic of research in recent literature. Adsorptive membranes, which include these nanosorbents, combine the benefits of adsorption with membrane separation, allowing for high flow rates and faster adsorption/desorption rates, and have received a lot of publicity in recent years. The most recent advances in the fabrication of adsorptive membranes (including homogeneous membranes, mixed matrix membranes, and composite membranes), as well as their basic principles and applications in water and wastewater treatment, are discussed in this review. This paper covers ten years, from 2011 to 2021, and examines over 100 published studies, highlighting that micropollutans can pose a serious threat to surface water environments and that adsorptive membranes are promising, particularly in the adsorption of trace substances with fast kinetics. Membrane fouling, on the other hand, should be given more attention in future studies due to the high costs and restricted reusability.


Subject(s)
COVID-19 , Nanotubes, Carbon , Water Pollutants, Chemical , Water Purification , Adsorption , Humans , Pharmaceutical Preparations , Water , Water Pollutants, Chemical/analysis , Water Purification/methods
15.
Biosensors (Basel) ; 12(3)2022 Feb 28.
Article in English | MEDLINE | ID: covidwho-1715108

ABSTRACT

Current point-of-care (POC) screening of Coronavirus disease 2019 (COVID-19) requires further improvements to achieve highly sensitive, rapid, and inexpensive detection. Here we describe an immunoresistive sensor on a polyethylene terephthalate (PET) film for simple, inexpensive, and highly sensitive COVID-19 screening. The sensor is composed of single-walled carbon nanotubes (SWCNTs) functionalized with monoclonal antibodies that bind to the spike protein of SARS-CoV-2. Silver electrodes are silkscreen-printed on SWCNTs to reduce contact resistance. We determine the SARS-CoV-2 status via the resistance ratio of control- and SARS-CoV-2 sensor electrodes. A combined measurement of two adjacent sensors enhances the sensitivity and specificity of the detection protocol. The lower limit of detection (LLD) of the SWCNT assay is 350 genome equivalents/mL. The developed SWCNT sensor shows 100% sensitivity and 90% specificity in clinical sample testing. Further, our device adds benefits of a small form factor, simple operation, low power requirement, and low assay cost. This highly sensitive film sensor will facilitate rapid COVID-19 screening and expedite the development of POC screening platforms.


Subject(s)
Biosensing Techniques , COVID-19 , Nanotubes, Carbon , Biosensing Techniques/methods , COVID-19/diagnosis , Humans , Limit of Detection , Point-of-Care Systems , SARS-CoV-2
16.
Int J Nanomedicine ; 17: 751-781, 2022.
Article in English | MEDLINE | ID: covidwho-1714853

ABSTRACT

Since December 2019, the world has faced an unprecedented pandemic crisis due to a new coronavirus disease, coronavirus disease-2019 (COVID-19), which has instigated intensive studies on prevention and treatment possibilities. Here, we investigate the relationships between the immune activation induced by three coronaviruses associated with recent outbreaks, with special attention to SARS-CoV-2, the causative agent of COVID-19, and the immune activation induced by carbon nanotubes (CNTs) to understand the points of convergence in immune induction and modulation. Evidence suggests that CNTs are among the most promising materials for use as immunotherapeutic agents. Therefore, this investigation explores new possibilities of effective immunotherapies for COVID-19. This study aimed to raise interest and knowledge about the use of CNTs as immunotherapeutic agents in coronavirus treatment. Thus, we summarize the most important immunological aspects of various coronavirus infections and describe key advances and challenges in using CNTs as immunotherapeutic agents against viral infections and the activation of the immune response induced by CNTs, which can shed light on the immunotherapeutic possibilities of CNTs.


Subject(s)
COVID-19 , Nanotubes, Carbon , Humans , Immunotherapy , Pandemics/prevention & control , SARS-CoV-2
17.
Sensors (Basel) ; 22(3)2022 Jan 21.
Article in English | MEDLINE | ID: covidwho-1686936

ABSTRACT

Rapid growth of personal electronics with concurrent research into telerehabilitation solutions discovers opportunities to redefine the future of orthopedic rehabilitation. After joint injury or operation, convalescence includes free active range of movement exercises, such as joints bending and straightening under medical supervision. Flexion detection through wearable textile sensors provides numerous potential benefits such as: (1) reduced cost; (2) continuous monitoring; (3) remote telerehabilitation; (4) gamification; and (5) detection of risk-inducing activities in daily routine. To address this issue, novel piezoresistive multi-walled carbon nanotubes/graphite/styrene-butadiene-styrene copolymer (CNT/Gr/SBS) fiber was developed. The extrusion process allowed adjustable diameter fiber production, while being a scalable, industrially adapted method of manufacturing textile electronics. Composite fibers were highly stretchable, withstanding strains up to 285%, and exhibited exceptional piezoresistive parameters with a gauge factor of 91.64 for 0-100% strain range and 2955 for the full scope. Considering the composite's flexibility and sensitivity during a series of cyclic loading, it was concluded that developed Gr/CNT/SBS fibers were suitable for application in wearable piezoresistive sensors for telerehabilitation application.


Subject(s)
Graphite , Nanotubes, Carbon , Telerehabilitation , Wearable Electronic Devices , Electric Conductivity , Humans
18.
J Mater Chem B ; 10(10): 1520-1552, 2022 03 09.
Article in English | MEDLINE | ID: covidwho-1684137

ABSTRACT

A favorable outcome of the COVID-19 crisis might be achieved with massive vaccination. The proposed vaccines contain several different vaccine active principles (VAP), such as inactivated virus, antigen, mRNA, and DNA, which are associated with either standard adjuvants or nanomaterials (NM) such as liposomes in Moderna's and BioNTech/Pfizer's vaccines. COVID-19 vaccine adjuvants may be chosen among liposomes or other types of NM composed for example of graphene oxide, carbon nanotubes, micelles, exosomes, membrane vesicles, polymers, or metallic NM, taking inspiration from cancer nano-vaccines, whose adjuvants may share some of their properties with those of viral vaccines. The mechanisms of action of nano-adjuvants are based on the facilitation by NM of targeting certain regions of immune interest such as the mucus, lymph nodes, and zones of infection or blood irrigation, the possible modulation of the type of attachment of the VAP to NM, in particular VAP positioning on the NM external surface to favor VAP presentation to antigen presenting cells (APC) or VAP encapsulation within NM to prevent VAP degradation, and the possibility to adjust the nature of the immune response by tuning the physico-chemical properties of NM such as their size, surface charge, or composition. The use of NM as adjuvants or the presence of nano-dimensions in COVID-19 vaccines does not only have the potential to improve the vaccine benefit/risk ratio, but also to reduce the dose of vaccine necessary to reach full efficacy. It could therefore ease the overall spread of COVID-19 vaccines within a sufficiently large portion of the world population to exit the current crisis.


Subject(s)
COVID-19 , Cancer Vaccines , Nanotubes, Carbon , COVID-19/prevention & control , COVID-19 Vaccines , Humans , SARS-CoV-2
19.
Talanta ; 239: 123113, 2022 Mar 01.
Article in English | MEDLINE | ID: covidwho-1540979

ABSTRACT

Carbonaceous immunosensors are ideal nanoplatforms for developing rapid, precise, and ultra-specific diagnostic kits capable of early detection of viral infectious illnesses such as COVID-19. However, developing a proper carbonic immunosensor requires stepwise protocols to find optimum operating conditions to minimize drawbacks. Herein, for the first time and through a stepwise protocol, activation, and monoclonal IgG antibody mounting capability of multi-walled carbon nanotubes (MWCNTs) at two diverse outer diameters (ODs), viz., 20-30 nm and 50-80 nm, and graphene deriv atives (graphene oxide (GO) and reduced graphene oxide (rGO)) were examined and compared with each other toward finding the prime carbonaceous nanomaterial(s) for maximized antibody loading efficiency along with an ideal detection limit (DL) and sensitivity. Next, the effect of common amplifying agents, i.e., Au nanostars (Au NSs) and Ag nanowires (Ag NWs), on the total performance of the best carbonaceous structure was carefully assessed, and the responsible detection mechanism is investigated in detail. Next, the developed carbonaceous immunosensors were assessed via voltammetric and impedance assays, and their performances toward specific detection of SARS-CoV-2 antigen through immunoreaction were examined in detail. The study's outcome showed the superior performance of conjugated rGO-based immunosensor with Au NSs toward specific and quick (1 min) detection of SARS-CoV-2 antigen in biological fluids compared with other 1D/2D carbonaceous nanomaterials.


Subject(s)
Biosensing Techniques , COVID-19 , Graphite , Nanostructures , Nanotubes, Carbon , Electrochemical Techniques , Humans , Immunoassay , SARS-CoV-2
20.
Infect Genet Evol ; 96: 105155, 2021 12.
Article in English | MEDLINE | ID: covidwho-1525880

ABSTRACT

The present study aimed to predict the binding potential of carbon nanotube and nano fullerene towards multiple targets of SARS-CoV-2. Based on the virulent functions, the spike glycoprotein, RNA-dependent RNA polymerase, main protease, papain-like protease, and RNA binding domain of the nucleocapsid proteins of SARS-CoV-2 were prioritized as the molecular targets and their three-dimensional (3D) structures were retrieved from the Protein Data Bank. The 3D structures of carbon nanotubes and nano-fullerene were computationally modeled, and the binding potential of these nanoparticles to the selected molecular targets was predicted by molecular docking and molecular dynamic (MD) simulations. The drug-likeness and pharmacokinetic features of the lead molecules were computationally predicted. The current study suggested that carbon fullerene and nanotube demonstrated significant binding towards the prioritized multi-targets of SARS-CoV-2. Interestingly, carbon nanotube showed better interaction with these targets when compared to carbon fullerene. MD simulation studies clearly showed that the interaction of nanoparticles and selected targets possessed stability and conformational changes. This study revealed that carbon nanotubes and fullerene are probably used as effectual binders to multiple targets of SARS-CoV-2, and the study offers insights into the experimental validation and highlights the relevance of utilizing carbon nanomaterials as a therapeutic remedy against COVID-19.


Subject(s)
Fullerenes/metabolism , Nanotubes, Carbon , SARS-CoV-2/metabolism , Viral Proteins/chemistry , Antiviral Agents/chemistry , Antiviral Agents/metabolism , Coronavirus 3C Proteases/chemistry , Coronavirus 3C Proteases/metabolism , Coronavirus Nucleocapsid Proteins/chemistry , Coronavirus Nucleocapsid Proteins/metabolism , Coronavirus Papain-Like Proteases/chemistry , Coronavirus Papain-Like Proteases/metabolism , Fullerenes/chemistry , Fullerenes/pharmacokinetics , Humans , Molecular Docking Simulation , Molecular Dynamics Simulation , Nanotubes, Carbon/chemistry , Phosphoproteins/chemistry , Phosphoproteins/metabolism , RNA-Dependent RNA Polymerase/chemistry , RNA-Dependent RNA Polymerase/metabolism , SARS-CoV-2/chemistry , Spike Glycoprotein, Coronavirus/chemistry , Spike Glycoprotein, Coronavirus/metabolism , Viral Proteins/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL